Mining Equipment
- Mine Car & Wheel Set
- Mining Man Car
- Large Equipment
- Mine Locomotive
- Muck Shovel Loader
- Mucking Machine
- Scraper Conveyor
- Belt Conveyor
- Air Compressor
- Mine Communication
- Overhead Passenger Device
- Ventilation Equipment
- Monorail Crane
- Roadheader Machine
- Mining LHD
- Coal Shearer
- Coal Cutter
- Mine Car Dumper
- Mining Electric Appliance
- Rail Catcher
-
Mining Railway Equipment
-
Mining Support Equipment
-
Mining Lift Equipment
-
Mining Safety & Protection Equipment
-
Construction Machine
-
Mining Drill Equipment
-
Steel Rail
-
Pump Equipment
-
Instrument And Meter
-
UAV

K45 Energy Efficient Power Saving Mine Ventilation Fans
K45 type mine energy-saving ventilation is a model of axial ventilation, because of its use of industry and application areas are unique, as well as in performance parameters and dimensions with large
Related Products- info@chinacoalintl.com
- +86-18660761303
- Please Leave a Message
Payment Terms: TT, Western Union ,Paypal MOQ:Contact us to confirm
Related Products of K45 Energy Efficient Power Saving Mine Ventilation Fans
Introduction of K45 Energy Efficient Power Saving Mine Ventilation Fans
K45 type mine energy-saving ventilation is a model of axial ventilation, because of its use of industry and application areas are unique, as well as in performance parameters and dimensions with large differences in generally axial ventilation, so separate out normalized to do a class.
Technology parameter of K45 Energy Efficient Power Saving Mine Ventilation Fans
No. |
Rotate Speed r/min |
Air Volume m3/s |
Full Pressure Pa |
Power (kW) |
7 |
980 |
3.0~5.7 |
125~240 |
1.5 |
8 |
1450 |
6.6~12.5 |
357~685 |
7.5 |
980 |
4.5~8.4 |
163~313 |
3 |
|
9 |
1450 |
9.5~17.8 |
452~867 |
15 |
980 |
6.4~12.0 |
207~396 |
5.5 |
|
10 |
1450 |
13.0~24.0 |
558~1071 |
30 |
980 |
8.7~16.5 |
255~489 |
7.5 |
|
11 |
1450 |
17.3~32.6 |
675~1295 |
45 |
980 |
11.6~22.0 |
309~592 |
15 |
|
12 |
1450 |
22.5~42.3 |
804~1542 |
75 |
980 |
15.1~28.5 |
367~704 |
18.5 |
|
13 |
1450 |
28.6~53.8 |
943~1810 |
90 |
980 |
19.2~36.3 |
431~827 |
30 |
|
14 |
1450 |
35.7~67.2 |
1094~2099 |
132 |
980 |
23.9~45.3 |
500~959 |
45 |
|
15 |
1450 |
43.9~82.6 |
1256~2409 |
200 |
980 |
29.4~55.7 |
574~1101 |
55 |
|
16 |
980 |
35.7~67.6 |
653~1252 |
90 |
17 |
980 |
42.8~81.1 |
737~1414 |
110 |
18 |
980 |
50.9~96.2 |
826~1585 |
160 |
19 |
980 |
59.8~113.2 |
920~1766 |
200 |
20 |
980 |
69.8~132.0 |
1019~1956 |
250 |
Rules and use
To ensure long-term security mine ventilation operation should be noted that the proper use and regular maintenance. Roadway using withdrawable mixing ventilation fan should meet the "Coal Mine Safety Regulations" the relevant provisions. Fans should be set before security shutters, open the safe before starting ventilator shutters, in normal operation, gradually close the security shutters. Should be checked before starting ventilator fan and a switch near 1 0 m less gas content, gas concentration does not exceed 0.5%, before starting fan, if the gas gauge should take the appropriate measures. Fan in operation stopped due to a fault, restart, should detect wind Jane Nevas concentration, if the gas concentration is exceeded, shall be mine safety rules regulations.
Photos of K45 Energy Efficient Power Saving Mine Ventilation Fans

Star Rating: |
Product Feedback
History Feedback: (13)
Latest Feedback