Emergency locking switch brief introduction
KGT Emergency locking switch consists of housing, limit switch, emergency stop pull ring, ring-pull reset, terminals and other components.
KGT Emergency locking switch is suitable for hazardous areas with mixed gas and coal mine, coal preparation plant workplaces such as mine belt conveyor integrated protection and control devices for emergency stop signal detection purposes.
Emergency locking switch parameters:
contact capacity : 30V/10A
contact resistance : ≤0.1Ω
vibration,shock : ≤0.2Ω
operating force : 60N±10N
reset force : 60N±10N
self weight : 3kg
dimension : 165mm×90mm×160mm
Emergency locking switch working principle:
On either side of the ring emergency stop switch,pull outward force applied 60N ± 10N and generate displacement, limit switch inside KGT emergency locking switch action, contact state flip, and self-locking; pull ring in the corresponding reset 60N ± 10N applied on the outside force when, KGT emergency locking switch inside the limit switch operates again, the contact state recovery.
Emergency locking switch photo
Because of the production batch, the specific model are different, the above pictures are only for reference , you can contact our sales staff for further details on the specific verification.
B/L of the History Trading