Product Introduction
Features of Loop Calibrator
The fast, one-handed tool for loop checks. Just click to calibrate.
This feature-rich solution combines the best features push-button and knob-base loop calibrator and offers:
Large display and simple, quick-click interface for easy one-handed operation.
mA accuracy of 0.025%, superior to other loop calibrators in this price range.
Simultaneous mA and % readout for quick, easy interpretation of readings.
1 μA resolution for mA source, simulate and measure.
Selectable slow ramp, fast ramp, and step ramp to provide smooth outputs for valve slewing and loop functional tests.
0-100% ‘span check’ for fast confirmation of zero and span.
24 volt internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM.
HART ? mode connects 250 Ω resistor in series with 24 V loop for compatibility with HART communicators.
Measures V dc to 28 V.
Single 9V battery that is easily changed without braking calibration seal
Push button 25% steps for fast, easy linearity checks.
0 - 20 mA or 4 - 20 mA default start up modes.
Innovative output adjustment dial with 1 μA and 100 resolution.
Main Parameter
Current Measurement
|
Range:
|
0 to 24 mA
|
Resolution:
|
0.001 mA
|
Accuracy:
|
0.025% Rdg + 2 LSD
|
Current Sourcing
|
Range:
|
0 to 20 mA or 4 to 20 mA
|
Accuracy:
|
0.025% Rdg + 2 LSD
|
Drive Capability:
|
1200 Ω; 950 Ω at 20 mA in HART mode
|
Current Simulation
|
Range:
|
0 to 20 mA or 4 to 20 mA
|
Accuracy:
|
0.025% Rdg + 2 LSD
|
Ext. loop voltage requirement:
|
12-30 V
|
Loop Power
|
While measuring mA, 24 V
|
Voltage measurement
|
Range:
|
0 to 28 V DC
|
Resolution:
|
1 mV
|
Accuracy:
|
0.025% Rdg + 2 LSD
|
Environmental Specifications
|
Operating Temperature
|
-10oC to 55oC
|
Storage Temperature
|
-30oC to 60oC
|
Humidity (Without Condensation)
|
0 to 90% (0oC to 35oC); 0 to 70% (35oC to 55oC)
|
Temperature Coefficient
|
-10oC to 18oC, 28oC to 55oC, ±.005% of range per oC
|
Figure Photos

B/L of The History Trading