Introduction Of Biogas detector
This device can be used for detecting any 4 gases, we can make the combination according to customers’ requirements.
Parameters Of Biogas detector
ases detected
|
CH4/LEL, O2, H2S, CO
|
Measuring range
|
CH4: (0.00—5.00)%Vol
LEL: (0 ~ 100)%LEL
O2: (0~30.0)%vol, (0~100)%vol
H2S: (0 ~ 100)ppm
CO: (0~1000) ppm
|
Resolution ratio
|
CH4: 0.01%vol,
LEL: 1%LEL,
O2: 0.1%vol
H2S:1ppm,
CO: 1ppm
|
Sensor
|
Electrochemical and catalytic sensors
|
Sensor lifetime
|
≥2year( CO, O2, H2S )
≥1year( LEL, CH4 )
|
Response time
|
CH4: ≤20S ( T90 ),
LEL: ≤20S ( T90 )
O2: ≤35s(T90),
H2S: ≤45S ( T90 )
CO: ≤45s (T90)
|
Alarms
|
Audible--buzzer with ≥80dB audible
Visible--flashing red LED, ≥20m visible
|
Alarm point
|
Fully adjustable
|
Data logging (optional)
|
Continuous data logging (7 days at
configurable 0.1-10 minutes intervals)
|
Continuous working time
|
≥13hours
|
Display
|
Liquid Crystal Display(LCD)
|
Battery model
|
PL123450, 3.7V/1500mA
|
Charging time
|
4-5 hours
|
Dust and water resistance
|
IP65
|
Size & Weight
|
130*66*30mm, 500g
|
Ex sign
|
ExibdⅠ
|
Pictures Of Biogas detector