- Mine Car & Wheel Set
- Mine Locomotive
- Mucking Machine
- Rock Loader
- Scraper Conveyer
- Belt Conveyor
- Air Compressor
- Ventilation Equipment
- Roadheader Machine
- Mining LHD
- Coal Shearer
- Mine Car Dumper
- Mining Electric Appliance
- Mine Communication
- Steel Rail
- Track Switch
- Rail Transit Equipment
- Rail Arrester
- Railway Sleepers
- Railway Parts
- Mining Steel
- Steel Shot
- U Channel Steel Support
- Hydraulic Acrow Props
- Hydraulic Roof Supports
- Hinged Bar
- Anchor Bolt
- Anchor Agent
- Gas Detector
- Concrete Rebar Detector
- Flowmeter
- Radiation Dosimeter
- Testing Meter
- Moisture Meter
- Water Finder
- Metal Detector
- Hardness Tester
- Flaw Detector
- Pipe Inspection Camera
- Engineering Instrument
- Pipe Leak Detector
- Guniting Equipment
- Wall Rendering Machine
- Construction Mixer
- Mobile Concrete Mixer Truck
- Road Roller Compactor
- Road Construction Machine
- Excavator
- tipper truck, dump truck, mining truck
- Pile Driver
- Light Tower
- Athletic Field Equipment
- Concrete Saw Cutter
- Rebar Tying Machine
- Rebar Cutter and Bender
- Shipping Container
Mining Equipment
Railway Equipment & Steel Rail
Drilling Equipment
Supporting Equipment
Lifting Equipment
Safety & Protection Equipment
Instrument And Meter
Construction Machine
Mineral Processing Equipment
Pump Equipment

Don't let your body be a filter!
Oil production, chemical production, mining, metallurgy, fire and rescue prevention in the production process will produce large amounts of toxic gas dust, steam, hypoxia, toxic particles, long time exposure may cause respiratory tract, lung, heart, blood and other diseases, and even cause cancer and may.
-
Mine exploitation
-
Fire rescue
-
metallurgy
-
Chemical production

Enjoy the fresh air
Lower respiratory resistance and breathe comfortably

- Protective gas
- Protective smoke
- Protective dust
- Isolated steam
- Isolated particle
- Isolated hypoxia
Scope of application
A. smoke, oxygen and any atmosphere contaminated by gas, smoke and steam;
B.-30 degrees C~+60 degrees C, relative humidity 0~100%, atmospheric pressure
70KPa~125KPa in the atmospheric environment.
Oxygen Breathing Apparatus
Three core strengths

Exquisite
details
/01
In accordance with the back suspension system design is the principle of human body engineering structure (small size) and weight (the 8kg) improved to ensure that the ctivities of freedom but also reduce the labor burden, ensure the buffer belt respirator during the transportation and use security, users can quickly back on and off.

02\
Decompression
Science
Reliable cylinder valve and pressure reducer connection system, pressure reducer pressure relief system; pipeline adopted quick connector type connection with good sealing performance, streamlined carbon dioxide filtration system to expel the CO2 absorption more fully.

Efficient
cooling
/03
In order to reduce the temperature of the inhaled gas and reduce the physiological burden of the user, the cooling device adopts blue ice or ice cubes and adds a manual drainage system.
Oxygen Breathing Apparatus
Usage method

01
Lift the bottom of the air breathing bottle to the shoulders.
02
Insert your thumb into the buckle of the shoulder strap and pull it down to adjust it to the comfortable shoulder.
03
Insert the plastic quick socket, fasten the belt to comfort and back swing is better (not three pre adjustable belt on both sides of the first before wearing mouth).
04
The chin is covered with a face mask, and the upper cover is pulled upwards, and the elastic belt on both sides of the net cover is tight, so that the double cover ring of the full cover is close to the face.
05
Take a deep breath and open the gas valve. Breathe several times, feel comfortable, breathe properly, you can enter the operation area.
06
Use the uninstall method after the end of the:
1.Pull the elastic buckle off the sides of the mask, loosen the elastic, and remove the mask from the bottom up.
2.Press the manual switch with indication arrow on the air supply valve and turn off the air supply valve.
3.Remove the belt plug from the socket.
4.Relax the straps and remove the respirator from the shoulder.
5.Close the cylinder valve switch, open the bypass valve, vent the residual gas in the system pipe, and then turn off the bypass valve.
Choose me
Give you the freshness of nature
Keep away from toxic and harmful gases and prevent the risk of hypoxia
Oxygen Breathing Apparatus
technical parameter
Item
Type
Duration
Working pressure for oxygen bottle
Capacity for oxygen bottle
Oxygen storage
Dimensions
Weight
Breathing rate
Exhaling resistance
Inhaling resistance
Fixed Oxygen-supplying
Manual or automatic oxygen-supplying
Start pressure for Auto-supplying valve
Inhaling Carbon dioxide concentration
Inhaling oxygen concentration
Warning pressure for alarm
Warning time for alarm
Sound level
- Specification
- HYZ-2
- HYZ-4
- HYZ-4B
- 120 min
- 240 min
- 240min
- 20 MPa
- 20 MPa
- 20 MPa
- 1.4L
- 2.4L
- 3.0L
- 280L
- 480L
- 600L
- 518×370×160mm
- 560×370×160mm
- 580x430x190 mm
- 11kg
- 12kg
- 12kg
- 30L/min
- (0~600)Pa
- (0~600)Pa
- ≤700Pa
- ≥(1.4~1.7)L/min
- 1.6±0.2L/min
- ≥80L/min
- 100L/min
- (10~245)Pa
- (10~245)Pa
- ≤1%
- ≤1%
- >21%
- >21%
- (4~6)MPa
- (4~6)MPa
- (30~60)s
- (30~60)s
- ≥80dB
- 90b